Deleting Spares; Recognizing A Failed Unit - HP StorageWorks Modular Smart Array 1000 cs User Manual

Command line interface
Table of Contents

Advertisement

Deleting spares

To remove a spare from use:
Basic command
Example command
Command options

Recognizing a failed unit

If all drives of a previously failed unit are in working order, use this command to
change the state of the unit back to VOLUME_OK.
To accept media exchange on a unit marked as failed:
Basic command
Example command
Command options
Modular Smart Array 1000/1500 cs Command Line Interface User Guide
DELETE SPARE
CLI> DELETE SPARE UNIT=2 DISK109
—the unit that will no longer have access to the spare. This is the same
UNIT 2
number that was given to the unit when it was created with the ADD UNIT
command. In this example, LUN 2 will no longer have access to the spare.
—the spare drive to remove from use. Disks are identified by box
DISK109
number and bay number. In this example, drive 1 in box number 9 will no
longer be used as a spare for LUN 2.
ACCEPT UNIT
ACCEPT UNITS
CLI> ACCEPT UNIT 2
—the unit that you want to activate, where # represents the unit number.
#
If a unit number is not specified, all units will be reset.
Using the CLI
45