To view information about the configuration of the controller:
Basic command
Example command
Example CLI response
Note:
Modular Smart Array 1000/1500 cs Command Line Interface User Guide
SHOW THIS_CONTROLLER
SHOW OTHER_CONTROLLER
CLI> SHOW THIS_CONTROLLER
Controller:
MSA1000© Hewlett-Packard xxx Version 4.24 Build 122 Hardware 7
Component Enclosure.
Controller Identifier: 123
NODE_ID=yyyyyyyy-yyyyyyyy
SCSI_VERSION=SCSI-3
Supported Redundancy Mode: Active/Standby
Current Redundancy Mode: Not Redundant (No Failure)
Device Port SCSI address 6
Terminal speed for the CLI is set to 19200.
Host Port_1:
REPORTED PORT_ID YYYYYYYYY-YYYYYYYYY
PORT_1_TOPOLOGY=F_Port
Cache:
128 megabytes read cache
Cache is GOOD, and Cache is enabled
No unflushed data in cache
Battery:
Module #1 is fully charged and turned off.
Controller Up Time:
5 Days 06 Hours 01 Minutes 51 Seconds
Health:
Surface Scan:
Rebuild Status: Complete.
Expansion:
For Fibre Channel Arbitrated Loop environments, host port information includes:
Host Port_1:
REPORTED PORT_ID YYYYYYYYY-YYYYYYYYY
PORT_1_TOPOLOGY=L_Port
Hard Addressing enabled
LOOP_ID=1, ALPA=0xE8
128 megabytes write cache
Complete.
Running, LUN X (Y% Complete.)
Using the CLI
Version 2
27
Need help?
Do you have a question about the StorageWorks Modular Smart Array 1000 cs and is the answer not in the manual?
Questions and answers