Assigning A Name Or Id To A Lun; Adding A Spare To A Lun - HP StorageWorks Modular Smart Array 1000 cs User Manual

Command line interface
Table of Contents

Advertisement

Assigning a name or ID to a LUN

If desired (or required by your operating system), each LUN can be assigned a
unique name or ID in addition to its number. These user-defined names make it
easier to identify specific LUNs in other configuration procedures.
Note:
entire SAN for this OpenVMS system may share ID numbers. LUNs in different storage
systems must have different IDs.
Basic command
Example command
Command options
Example CLI response

Adding a spare to a LUN

To add a spare to an existing LUN:
Basic command
Example command
Command options
Modular Smart Array 1000/1500 cs Command Line Interface User Guide
OpenVMS systems require each LUN to have a unique ID. No two devices in the
SET UNIT_ID
CLI> SET UNIT_ID 0 ABC
LUN 0 is being assigned a name
0
is the name to assign to LUN 0. The name of this LUN will be ABC
ABC
Identifier "ABC" created for unit 0
ADD SPARE
CLI> ADD SPARE UNIT=2 DISK109
—the unit to assign the spare to. This is the same number that was
UNIT=2
given to the unit when it was created with the ADD UNIT command. In this
example, LUN 2 will have use of the spare.
—indicates the drives to assign as the spare to the LUN. Disks are
DISK109
identified by box number and bay number. In this example, drive 9 in box
number 1 is to be used.
.
Using the CLI
.
43

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks Modular Smart Array 1000 cs and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Storageworks modular smart array 1500 cs

Table of Contents