Viewing LUN information
The following information can be displayed for the LUN:
Basic command
Example command
To display all defined LUNs:
To display a specific LUN:
Example CLI response
Modular Smart Array 1000/1500 cs Command Line Interface User Guide
Unit identifier (user-defined name)
LUN status, including OK, Failed, and Rebuilding
List of the disks included in the LUN
List of the disks assigned as spares to the LUN
RAID level
Unit size, in MB
SHOW UNIT
CLI> SHOW UNITS
CLI> SHOW UNIT 1
Unit 1:
In PDLA mode, Unit 1 IS LUN 2; In VSA mode, Unit 1 is LUN 1
Unit Identifier:
Device Indentifier:600805F3-00006B20-AE277D4B-B0D100F7
Cache Status:Enabled
Max Boot Partition:Disabled
Volume Status: VOLUME OK
Parity Init Status: 3% complete
5 Data Disk(s) used by lun 1:
Disk107: Box 1, Bay 07,
Disk108: Box 1, Bay 08,
Disk207: Box 2, Bay 07,
Disk208: Box 2, Bay 08,
Spare Disk(s) used by lun 1:
No spare drive is designated.
Logical Volume Raid Level:
stripe_size=16KB
Logical Volume Capacity: 173,658MB
(SCSI bus 0, SCSI id 8)
(SCSI bus 1, SCSI id 0)
(SCSI bus 2, SCSI id 8)
(SCSI bus 2, SCSI id 9)
DISTRIBUTED PARITY FAULT TOLERANCE (RAID5)
Using the CLI
25
Need help?
Do you have a question about the StorageWorks Modular Smart Array 1000 cs and is the answer not in the manual?