Making Measurements
Measuring Multiple Signals
Resolving Signals of Equal Amplitude
In this example a decrease in resolution bandwidth is
used in combination with a decrease in video bandwidth
to resolve two signals of equal amplitude with a
frequency separation of 100 kHz.
Notice that the final RBW selected is the same width as
the signal separation while the VBW is slightly narrower
than the RBW.
1 Connect two sources to the analyzer input as shown
below.
Figure 4-2
Remot e
Standby
On
Signal generator
Rem ote
Standby
O n
Signal generator
2 Set one source to 300 MHz. Set the frequency of the
other source to 300.1 MHz. Set both source
amplitudes to –20 dBm.
3 Setup the analyzer to view the signals:
Use the knob or the arrow keys to further reduce the
resolution bandwidth and better resolve the signals.
40
Setup for obtaining two signals
N 9310A
FUN CTION S
RF Sig nal Generator
9 kHz - 3.0 GHz
Frequency
AM
I/Q
U tility
Pr eset
Amplit ude
FM
Sw eep
File
Local
Ent er
M
Pulse
Trig ger
LF Out
7
8
9
M OD
On/ Off
4
5
6
1
2
3
0
·
RF
On/ Off
LF OUT
RF OU T 50
REVERSE PW R
4W M AX 30VDC
FUN CTIONS
N9310A
RF Signal G enerator
9 kHz - 3.0 GHz
Frequency
AM
I/ Q
Ut ility
Preset
Am plitude
FM
Sw eep
File
Local
Enter
M
Pulse
Trigger
LF Out
7
8
9
M O D
O n/ Off
4
5
6
1
2
3
·
0
RF
On/ Off
LF OUT
RF OUT 50
REVERSE PWR
4 W MA X 30 VD C
Press [PRESET]
Press [FREQ] > 300.05 > {MHz}
Press [SPAN] > 2 > {MHz}
Press [BW/SWP] > 30 > {kHz}