Keysight Technologies N9340B User Manual page 129

Handheld spectrum analyzer
Hide thumbs Also See for N9340B:
Table of Contents

Advertisement

The mak types for IBOC-FM are listed as below:
FCC (FM-73.317)
NRSC-5-B Hybrid
NRSC-5-B Hybrid
Figure 5-2 IBOC (FM) spectral emission mask and limits
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
-110
-600
-400
Trace in
red
is FCC spectral emissions mask.
Trace in
blue
is NRSC hybrid spectral emissions limits.
Trace in Black is NRSC all digital spectral emissions limits.
• Mask On/Off
Mask On/Off is a switch to enable the mask function.
Set Span and RBW according to mask standard
automatically.
Set Average Type to Power and Detector to
Average (RMS), and also set average on with
average times to meet the measurement
specification.
• Pass/Fail
Pass/Fail On/Off is a switch to enable/disable
PASS/FAIL verification.
• Beep
Beep On/Off is a switch to enable/disable Pass/Fail
beep sound indication.
IBOC (FM) spectral emission mask and limits
-200
0
Offset from carrier frequency (kHz)
Key Reference
200
400
600
MODE
123