Group E: Function Control Parameters; E0: Set Point And Control Parameters - REXROTH VFC 3610 Quick Start Manual

Frequency converter
Hide thumbs Also See for VFC 3610:
Table of Contents

Advertisement

Rexroth Frequency Converter VFC
3610 / VFC 5610

3.4.4 Group E: Function Control Parameters

E0: Set point and control parameters

Code
E0.00 First frequency setting source
E0.01 First run command source
E0.02 Second frequency setting source 0...21
E0.03 Second run command source
Frequency setting source
E0.04
combination
Digital setting frequency
E0.06
saving mode
E0.07 Digital setting frequency
E0.08 Maximum output frequency
E0.09 Output frequency high limit
E0.10 Output frequency low limit
E0.11 Reverse running frequency
E0.15 Low speed running setting
E0.16 Low speed frequency hysteresis
E0.17 Direction control
E0.18 Direction change dead time
Acceleration / deceleration
E0.25
curve mode
E0.26 Acceleration time
E0.27 Deceleration time
E0.28 S-curve starting phase factor
E0.29 S-curve stopping phase factor
E0.35 Start mode
Name
0...21
0...2
0...2
0...6
0...4
0.00...[E0.09] Hz
50.00...400.00 Hz
[E0.10]...[E0.08] Hz
0.00...[E0.09] Hz
0.00...[E0.09] Hz
0: Run with 0.00 Hz
1: Run with low limit
frequency
0.00...[E0.10] Hz
0: Forward / Reverse
1: Forward only
2: Reverse only
3: Swap default direction
0.0...60.0 s
0: Linear mode
1: S-curve
0.1...6,000.0 s
0.1...6,000.0 s
0.0...40.0 %
0.0...40.0 %
0: Start directly
1: DC-braking before start
2: Start with speed tracing
3: Automatic start / stop ac-
cording to setting frequency
Setting range
R912005518_Edition 16 Bosch Rexroth AG
51/91
Start-up
Default
Min.
Attri.
0
Stop
0
Stop
2
Stop
1
Stop
0
Stop
0
Stop
50.00
0.01
Run
50.00
0.01
Stop
50.00
0.01
Run
0.00
0.01
Run
0.00
0.01
Stop
0
Stop
0.00
0.01
Stop
0
Stop
1.0
0.1
Stop
0
Stop
DOM
0.1
Run
DOM
0.1
Run
20.0
0.1
Stop
20.0
0.1
Stop
0
Stop

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vfc 5610

Table of Contents