Operating Example - REXROTH VFC 3610 Quick Start Manual

Frequency converter
Hide thumbs Also See for VFC 3610:
Table of Contents

Advertisement

34/91
Start-up
Frequency converter status
Running at 0 Hz (set RefDir: FWD)
Running at 0 Hz (set RefDir: REV)
Frequency converter in RUN state (set Re-
fDir: REV)
Frequency converter in RUN state (set Re-
fDir: FWD)
Tab. 3-2: Frequency converter status
(8) Error / Warning information: Error / Warning code will be displayed in this
sector. Please refer to
(9) Permanent monitoring: By default, its display as "Actual output frequency" is
set by parameter U2.09. Value and unit of parameter will be displayed.
(10) Re / Lo: Re stands for 'Remote' and Lo for 'Local'. Its display is set via Loc /
Rem button or parameter U2.03.
(11) Panel Locked / Unlocked: Panel can be locked by the following ways:
Setting [U2.02] to '1', or
Pressing Func button with Loc button for longer than 3 s.
Panel can be unlocked by the following ways:
Setting [U2.02] to '0' (only in communication mode), or
Pressing Func button with Loc button for longer than 3 s.

3.2.2 Operating Example

Please follow the steps below to set parameter [b0.10] to '1: Restore to default
settings' through LCD panel.
1. Press Func button.
2. Rotate Navigation button to select parameter group b0.
3. Press Navigation button and rotate it to select parameter b0.10.
4. Press Navigation button and rotate it to select parameter value '1: Restore
to default settings'.
5. Press Navigation button to finish setting.
Bosch Rexroth AG R912005518_Edition 16
: Blinking
: Invisible
: Invisible
: Invisible
: Blinking
: Invisible
: Invisible
: Shown solid, not blinking
: Invisible
: Shown solid, not blinking
: Invisible
: Invisible
chapter 4 "Diagnosis" on page 86
Rexroth Frequency Converter VFC
3610 / VFC 5610
Details
for details.