Group C: Power Parameters; C0: Power Control Parameters - REXROTH VFC 3610 Quick Start Manual

Frequency converter
Hide thumbs Also See for VFC 3610:
Table of Contents

Advertisement

Rexroth Frequency Converter VFC
3610 / VFC 5610

3.4.3 Group C: Power Parameters

C0: Power control parameters

Code
Name
Control mode
C0.00
(VFC 5610 only)
Normal / Heavy duty
C0.01
setting
C0.05 Carrier frequency
Carrier frequency
C0.06
automatic adjustment
C0.07 PWM mode
DPWM switchover fre-
C0.08
quency upper limit
Automatic voltage sta-
C0.10
bilization
Automatic voltage sta-
C0.11
bilization
reference
voltage
Brake chopper start
C0.15
voltage
Brake chopper duty cy-
C0.16
cle
Overvoltage
C0.23
sion adjustment gain
Stall overvoltage hyste-
C0.24
resis voltage
Overvoltage prevention
C0.25
mode
Stall overvoltage
C0.26
prevention level
Setting range
0: V/f control
1: Sensorless vector control
0: ND (Normal duty)
1: HD (Heavy duty)
0K40...22K0: 1...15 kHz
30K0...220K: 1...12 kHz
0: Inactive
1: Active
2: Fixed carrier frequency
0: SVPWM
1: SVPWM with overmodulation
2: DPWM
3: DPWM with overmodulation
8.00...400.00 Hz
0: Always active
1: Always inactive
2: Inactive only during decelera-
tion
1P 200 VAC: 180...264 V
3P 380 VAC: 323...528 V
1P 200 VAC: 300...390 V
3P 380 VAC: 600...785 V
1...100 %
suppres-
0.00...10.00
0...100 V
0...4
1P 200 VAC: 300...390 V
3P 380 VAC: 600...785 V
Default
0
1
0K40...90K0: 4k
110K...220K: 2k
1
DOM
12.00
0
220
380
385
770
100
1.00
1P: 30
3P: 50
3
385
770
R912005518_Edition 16 Bosch Rexroth AG
41/91
Start-up
Min.
Attri.
Stop
Stop
1
Run
Stop
Run
0.01
Run
1
Stop
1
Stop
1
Stop
1
Stop
0.01
Run
1
Stop
Stop
1
Stop