Events and faults

13.4.7 Other events and faults

DTCO 1381 display
Picto.
AP
Error text
1)
For these messages the memory code (MC) is not shown in the display of the DTCO 1381.
Edition 07/2007
The DTCO 1381 can also monitor other system functions in addition
to the legally required functionality.
Other events and faults are not saved in the date memory.
The error code can be read-out over the diagnosis interfaces (CAN or
K-Line) with a test device, but it will not be shown on the display of
the DTCO 1381.
The messages in connection with the upgrade of the user software
of the DTCO 1381 (Software Upgrade) generally appear in English.
Detailed information on the messages in connection with the
upgrade of the user software of the DTCO 1381 (Software Upgrade)
is contained in the Technical Description "Software-Upgrade
DTCO 1381".
MC
Error code
Meaning, cause and measures
00000001C0
Pre-warning on the event "overspeed".
Possible causes
Measures
– Reduce speed.
– Check the function / configuration of the DTCO 1381,
Note
For this message the TCO status (Handling Information = HI)
is sent on the CAN bus and on the info interface (customer-
specific, deviating signal output possible).
The pre-warning time (0 - 60 s) for this message can be con-
figured.
00000005B3
The DTCO 1381 is not equipped with a software upgrade
module.
Measures
– No measures necessary.
Note
The DTCO 1381 cannot be upgraded.
Technical Description DTCO 1381
13.4 Messages and troubleshooting measures
Overspeeding.
Faulty configuration.
correct if necessary.
1)
1)
13 - 35

Advertisement

Table of Contents