List Of Faults And Alarms - Siemens SINAMICS V90 Getting Started

Pulse train, uss/modbus interface
Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

● Alarms
To acknowledge faults, proceed as follows:
Note
If you do not eliminate the cause(s) of the fault, it can appear again after no button operation for five seconds. Make sure
that you have eliminated the cause(s) of the fault.
You can acknowledge faults using RESET signal. For details, refer to Operating Instructions.
You can acknowledge faults on SINAMICS V-ASSISTANT. For details, refer to SINAMICS V-ASSISTANT Online Help.
7.2

List of faults and alarms

This section lists only common faults and alarms. To view the detailed information of all faults and alarms, call the online
help for an active fault/alarm in the SINAMICS V-ASSISTANT engineering tool.
Fault list
Fault
Description
F1000
Internal software error
F1001
Floating Point exception
F1002
Internal software error
F1003
Acknowledgment delay when accessing the
memory
F1015
Internal software error
F1018
Booting has been interrupted several times
F1030
Sign-of-life failure for master control
F1611
SI CU: Defect detected
F7011
Motor overtemperature
F7085
Open-loop/closed-loop control parameters
changed
F7093
Test signal error
F7403
Lower DC link voltage threshold reached
F7404
Upper DC link voltage threshold reached
Getting Started
A5E36037886-003, 04/2017
Fault
Description
F7800
Drive: No power unit present
F7801
Motor overcurrent
F7802
Infeed or power unit not ready
F7815
Power unit has been changed
F7900
Motor blocked/speed controller at its limit
F7901
Motor overspeed
F7995
Motor identification failure
F30001
Power unit: Overcurrent
F30002
DC link voltage, overvoltage
F30003
DC link voltage, undervoltage
F30004
Drive heat sink overtemperature
F30005
Power unit: Overload I
F30011
Line phase failure in main circuit
t
2
113