Technical data
2.1.5 Technical data
Measurement range
LCD
Installation angle of display
Character height
Operating voltage
Power consumption
External fuse protection (typical)
Operating temperature
Storage temperature
Pulse range v
Maximum frequency v
Pulse range n
Maximum frequency n
Inputs
Outputs
Interfaces
Accuracy (under test conditions)
EMC
Vibrations
Material of the connection pins
Buffer battery
Housing
Weight
Permissible installation position
Possible special equipment
Edition 07/2007
0 ... 220 km/h
2 lines with 16 characters each, illuminated, dimmable*
± 30°
6.3 mm
24 V DC or 12 V DC*
Standby typical
Operation max.
-25 °C ... +70 °C
-40 °C ... +85 °C
4000 to 25000 pulses/km
1,5 kHz
2000 to 64000 pulses/1000 revolutions
5 kHz
KITAS 2171, n-sensor*, additional inputs*
2 x v-pulses, 1 x 4 pulses/m, TCO warning output (FM LED)
Calibration interface, download interface, CAN interface, Info interface
➥ See chapter 8.2 "Permissible error limits", page 8-5.
RL 2006/28/EC
ISO 16750-3 sec. 4.1.3.2.4.2, test VIII code VA
Sinusoidal oscillations according to IEC 60068-2-6 test Fc:
2-11 Hz, ± 10 mm; 11 - 300 Hz, 5g, 3 x 15 h
Oscillations random according to IEC 60068-2-64 test Fh:
5 - 150 Hz, 0,02 g²/Hz, 3 x 16 h
Surface OL Cu Ag 6
Lithium cell 3,6 V 1/2 AA (type SB-AA02P)
Galvanized steel plate
~ 1300 g
± 45° off of horizontal
rpm registration, additional stylus, K-Line diagnosis interface,
customer-specific cover, customer-specific display and keypad illumi-
nation, customer-specific output circuit, customer-specific interfaces,
v-pulse output (D6), without CAN
* Option
Technical Description DTCO 1381
2.1 DTCO 1381
12 V DC*
24 V DC
30 mA
20 mA
5 A
3 A
5 A
5 A
2 - 11