Siemens VDO DTCO 1381 Technical Description page 256

Digital tachograph
Table of Contents

Advertisement

13.4 Messages and troubleshooting measures
DTCO 1381 display
Picto.
AP
Error text
1)
These warning messages will be displayed repetitively every hour until the cause is withdrawn.
2)
These warning messages are not saved in the date memory during calibration mode.
13 - 24
MC
Error code
Meaning, cause and measures
8000000800
The time in the DTCO 1381 is not correct.
Possible causes
Measures
– Check UTC time on the DTCO 1381 and use a test device
– Check the "Time" function of the DTCO 1381.
If the error message continues to appear despite these
measures, replace the DTCO 1381.
Comment
No driver or company cards will be accepted in order to
prevent inconsistent data.
8000000D33
Fault in the calibration memory.
Possible causes
Overview of the significant calibration parameters:
Measures
If the error message appears despite repetitive acknowl-
edgement, replace the DTCO 1381.
© Siemens VDO Automotive AG
The clock has stopped or is advancing incorrectly.
An internal cyclical test has determined that the time is
not plausible.
to correct if needed.
An internal cyclical test of significant calibration param-
eters has found a check sum error.
Vehicle identification number
Vehicle registration number
Characteristic coefficient (w-value)
Recording equipment constant (k-value)
Effective wheel circumference
Tire size
Maximum speed
UTC time
Odometer reading
Calibration date
Events and faults
1)
2)
1)
2)
Edition 07/2007