LTE-I Installation and Setup Guide
ULC Installation
(Zone mode)
Wiring the Fault Relay
You may wire and program the communicator's fault output trigger for fail-safe mode (see the
question "FLT REL ON Y/N").
To sense a communicator fault at the control panel, see the figure below and make the following
connections. Include the proper EOL resistor required by the control panel.
UL / ULC
Wiring the Fault Relay to a Control Panel Zone for Normally Closed Fault
Internet Connection
UL
Connect one end of the Ethernet cable to the communicator's RJ45 connector and the other end
to the cable/DSL router as shown in the figure below.
NOTE: Remember to program communication path to either IP or IP & Cell.
+12 V AUX
GND
TRIGGER
CONTROL PANEL
NOTE: DO NOT CONNECT THE COMMUNICATION
MODULE BACKUP BATTERY OR TRANSFORMER
FOR COMMERCIAL BURGLARY INSTALLATIONS.
Wiring the Zone 1 Input for Zone Trigger Mode
For Commercial Burglary, a 24 hour zone (supervisory) must be assigned on the
control panel, with the communicator's fault relay wired to that zone.
12V AUX
GND
ZONE IN (+)
CONTROL PANEL
For UL installations, the Ethernet connection between the communicator and the router
cannot exceed 12 feet with both the communicator and the router located within the same
room.
Use a Listed cable/DSL router suited for the application.
TB1
AC INPUT 1
1
NO CONNECTION
AC INPUT 2
NO CONNECTION
2
RED
ECP (+) VOLTAGE INPUT
3
BLK
GND
4
5
ZONE INPUT Z1/Z2
COMMUNICATION MODULE
TRANSFORMER
TB1
1
AC INPUT 1
AC INPUT 2
2
3
ECP (+) VOLTAGE INPUT
GND
4
2K EOL
RESISTOR
11
RAD FLT
COMMUNICATIONS
MODULE
12
J1
NO CONNECTION
IGSMHSCN-003-V0
BATTERY
J1