Wiring The Fault Relay; Internet Connection - Honeywell IntelliPath Series Installation And Setup Manual

Internet and cellular communicator
Hide thumbs Also See for IntelliPath Series:
Table of Contents

Advertisement

LTE-I Installation and Setup Guide
ULC Installation
(Zone mode)

Wiring the Fault Relay

You may wire and program the communicator's fault output trigger for fail-safe mode (see the
question "FLT REL ON Y/N").
To sense a communicator fault at the control panel, see the figure below and make the following
connections. Include the proper EOL resistor required by the control panel.
UL / ULC
Wiring the Fault Relay to a Control Panel Zone for Normally Closed Fault

Internet Connection

UL
Connect one end of the Ethernet cable to the communicator's RJ45 connector and the other end
to the cable/DSL router as shown in the figure below.
NOTE: Remember to program communication path to either IP or IP & Cell.
+12 V AUX
GND
TRIGGER
CONTROL PANEL
NOTE: DO NOT CONNECT THE COMMUNICATION
MODULE BACKUP BATTERY OR TRANSFORMER
FOR COMMERCIAL BURGLARY INSTALLATIONS.
Wiring the Zone 1 Input for Zone Trigger Mode
For Commercial Burglary, a 24 hour zone (supervisory) must be assigned on the
control panel, with the communicator's fault relay wired to that zone.
12V AUX
GND
ZONE IN (+)
CONTROL PANEL
 For UL installations, the Ethernet connection between the communicator and the router
cannot exceed 12 feet with both the communicator and the router located within the same
room.
Use a Listed cable/DSL router suited for the application.
TB1
AC INPUT 1
1
NO CONNECTION
AC INPUT 2
NO CONNECTION
2
RED
ECP (+) VOLTAGE INPUT
3
BLK
GND
4
5
ZONE INPUT Z1/Z2
COMMUNICATION MODULE
TRANSFORMER
TB1
1
AC INPUT 1
AC INPUT 2
2
3
ECP (+) VOLTAGE INPUT
GND
4
2K EOL
RESISTOR
11
RAD FLT
COMMUNICATIONS
MODULE
12
J1
NO CONNECTION
IGSMHSCN-003-V0
BATTERY
J1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellipath lte-ivIntellipath lte-iaIntellipath lte-ic

Table of Contents