General Information; Features; Supervision And Fault Detection - Honeywell LTE-X series Installation And Setup Manual

Sends alarms and messages to alarmnet
Table of Contents

Advertisement

General Information

The LTE-X Series Communicator, herein referred to as the communicator, easily connects to your security system's control
panel and sends alarms and messages to AlarmNet for subsequent transfer to the central monitoring station. It can be
mounted directly on the control panel or remotely.
The LTE-X Series includes the following models:
• LTE-XV (US, Verizon network)
• LTE-XA (US, AT&T network)
• LTE-XC (Canada)
The communicator requires an AlarmNet 360 account. For new installations, please obtain the account information
from the central station prior to programming.
The LTE-X communicates with AlarmNet over the LTE network. If a data connection cannot be established, it will
attempt to send a transmission via SMS.
In addition to alarm reporting, the communicator provides upload/downloading capability of Honeywell's control panel
data over the Internet using LTE technology.
NOTE: Due to Honeywell's continuing effort to improve our products, your device may look slightly different than
pictured.

Features

Reports fire, burg, and status message.
Internal MIMO antennas provide additional security.
Simple programming using the 7720P programming tool or via the AlarmNet 360 website.
Uses 2 way ECP communication with the control panel.
Sends reports in Contact ID format.
Supports remote control of alarm system via Remote Services feature.
Allows uploading and downloading of control panel data.
Fully powered (primary and backup battery) from the control panel.
The LTE-X is for control panels that support ECP communication.
NOTE: The control panel treats the communicator as an ECP device, so ensure the control panel is programmed with
the communicator's device address.

Supervision and Fault Detection

Network communication failure – In the event the AlarmNet network does not hear a supervisory message from
the communicator within a specified time ("Supervision" option, 24 hours, 30 days, or none), AlarmNet notifies
the central station of a communication failure.
Communication path failure – In the event the module detects a communication path failure, a trouble condition
is sent to the control panel. The failure is considered a true fault when the fault time has expired ("Cell Fault
Time" option) provided it has been set to a non-zero value. Notification can be sent to the central station upon
this expiration via the control panel's alternate means of communication (if available).
LTE-X Series Installation and Setup Guide