LTE-I Installation and Setup Guide
PROMPTS
IP Connection
77
(Present)
Review? Y/N
78

Exiting Programming Mode

To exit the programming mode, press [N] in response to the "REVIEW?" question. Then press
[Y] to the "Exit Prog Mode?" question. Upon exiting, the root file is updated to log the changes
made. A message is displayed telling the user that this step is being executed. When complete,
the message "DONE" is displayed to indicate the file was successfully uploaded.
If critical configuration changes were made, such as the mode of operation, the communicator
will reset to ensure that the programming features are enabled.
If the file is not successfully uploaded, one of the following prompts will be displayed. Follow the
steps shown below until the upload is successful.
Display
Cannot Upload
Try Again? Y/N_
Failed to Update
Root File!

Setting Factory Defaults

To reset the programming options to factory-default values, press [ESC] at the "Exit Prog Mode?"
prompt.
Set Default?
Y/N_
If you press [Y], all programmed values are reset to the original factory settings. PLEASE NOTE
THAT THIS WILL ERASE ANY PASSWORD THAT MAY HAVE BEEN ENTERED. After pressing
[Y], the Create Password prompt appears (see Prompt 4).
OPTIONS
DESCRIPTION
This prompt appears only if comm. path is set to IP & Cell.
 Present
Press the [space] key to toggle between the options. Press [ENTER] to
 Auto Detect
select the configuration.
If "Present" is chosen, it is assumed that an IP is connected to the device.
If it is not detected, a Primary Comm Path Failure message will be
delivered after the programmed fault time expires.
If "Auto Detect" is chosen, the device will always try to use IP to
communicate but it will not generate a Primary Comm Path Failure unless
it previously detected the presence of IP. As soon as the presence of IP
is detected, a Primary Comm Path Restore message is generated and the
value of IP Connectivity programming parameter is changed from "Auto
Detect" to "Detected".
From this point on, the software expects connectivity. The auto detect
logic will resume only when the parameter is changed back to "Auto
Detect".
Reviewing Programming Mode Entries
[Y] = review
To review the programming options (to ensure that the correct entries
[N] = exit
have been made), press [Y]. The programming questions are displayed
again. Use the up/down arrow keys to scroll through the program fields
without changing any of the values. If a value requires change, simply
type in the correct value. When the last field is displayed, the "REVIEW?"
question again appears.
Exiting the Program Mode
To exit the programming mode, press [N] in response to the "REVIEW?"
question, and refer to Exiting Programming Mode below.
Description
Communicator is not yet initialized.
Network problem, or you answered
"N" to "Cannot Upload Try Again?"
prompt.
Press [Y] to reset factory default values.
Press [N] to cancel this function.
What to do
Wait for RSSI LEDs to be lit.
Press [Y].
Initiate the Force Server Update
Command by pressing the [0] key; refer to
Section 5: Programmer Keyboard
Commands.
34

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellipath lte-ivIntellipath lte-iaIntellipath lte-ic

Table of Contents