Wiring for Zone Trigger Mode

To trip a zone using a positive trigger, the voltage level must be:
6V or greater = positive trigger. (Levels above +14V may cause damage to the unit.)
4V or less = restore.
To trip a zone using a negative trigger, the voltage level must be:
4V or less = negative trigger.
6V or greater = restore. (Levels above +14V may cause damage to the unit.)
Note: Remember to program the communicator zone for the desired trigger type.
Connect a wire from the triggering source (bell output, voltage trigger, etc.) of the control panel to
the zone input of the communicator, and connect a common ground between the communicator
and control panel. Examples of zone connections follow:
TRIGGERING DEVICE
TRIGGERING DEVICE
UL/ULC
 Zones should use EOL resistors, and be pro-
grammed as V+ Inverted or V– Inverted opera-
tion such that a cut line results in an alarm.
 Do not use zones 1 and 2 for UL installations.
GND
+ TRIGGER
(VOLTAGE: 6 to 13V)
Wiring the Zone 1 Input for a Positive (+) Trigger
GND
-
TRIGGER
(VOLTAGE 4 to 0V)
Wiring the Zone 1 Input for a Ground (-V) Trigger
Wiring the Zone 1 Input for EOL Supervised N.O./N.C. Triggers
TRANSFORMER
TB1
AC INPUT 1
1
AC INPUT 2
2
GND
4
5
ZONE INPUT Z1/Z2
COMMUNICATIONS
MODULE
TRANSFORMER
TB1
AC INPUT 1
1
AC INPUT 2
2
GND
4
5
ZONE INPUT Z1/Z2
COMMUNICATIONS
MODULE
TRANSFORMER
2K EOL
N.O.
RESISTOR
11
Section 2: Mounting and Wiring
BATTERY
J1
GSMV-005-V0
BATTERY
J1
GSMV-006-V0
TB1
1
AC
AC
2
GND
4
N.C.
ZONE INPUT Z1/Z2
5
J1
COMMUNICATIONS
MODULE
BATTERY

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellipath lte-ivIntellipath lte-iaIntellipath lte-ic

Table of Contents