Honeywell IntelliPath Series Installation And Setup Manual page 36

Internet and cellular communicator
Hide thumbs Also See for IntelliPath Series:
Table of Contents

Advertisement

LTE-I Installation and Setup Guide
PROMPTS
Rpt Zn3 ONLY if
46
Armed (N)_
Zn4 Trigger Type
47
(V+)_
48
Invert Zn4 Y/N
(N)_
49
Restore Zn4 Y/N
(Y)_
Delay Zn4 (secs)
50
(00)
Rpt Zn4 ONLY if
51
Armed (N)_
Zn5 Trigger Type
52
(V+)_
Invert Zn5 Y/N
53
(N)_
Restore Zn5 Y/N
54
(Y)_
Delay Zn5 (secs)
55
(00)_
Rpt Zn5 ONLY if
56
Armed (N)_
Enable Zn6 Y/N
57
(N)_
Zn6 Trigger Type
58
(V+)_
Invert Zn6 Y/N
59
(N)_
Restore Zn6 Y/N
60
(Y)_
Delay Zn6 (secs)
61
(00)_
Rpt Zn6 ONLY if
62
Armed (N)_
Enable Zn7 Y/N
63
(N)_
OPTIONS
[Y], [N]
 (V+)
 (V–)
 (EOLR)
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
[Y], [N]
 (V+)
 (V–)
 (EOLR)
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
[Y], [N]
[Y], [N]
 (V+)
 (V–)
 (EOLR)
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
[Y], [N]
[Y], [N]
DESCRIPTION
Reports alarms on zone 3 ONLY if the conditional zone (zone 7 in
zone trigger mode) is triggered (armed).
If [N], always reports alarms on zone 3.
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
UL/ULC: V+ must be set as inverted and V– as
non-inverted.
Inverts the alarm and normal states of the zone 4 trigger;
otherwise uses normal input signal.
Enables restore reporting for zone 4.
UL/ULC: Must be set to "Y."
Defines the reporting delay in seconds for zone 4.
UL/ULC: Must be set to "00."
Reports alarms on zone 4 ONLY if the conditional zone (zone 7 in
zone trigger mode) is triggered (armed).
If [N], always reports alarms on zone 4.
Selects the triggering method for this zone input.
Press the [space] key to scroll through the choices.
UL: V+ must be set as inverted and V– as
non-inverted.
Inverts the alarm and normal states of the zone 5 trigger;
otherwise uses normal input signal.
Enables restore reporting for zone 5.
UL/ULC: Must be set to "Y."
Defines the reporting delay in seconds for zone 5.
UL/ULC: Must be set to "00."
Reports alarms on zone 5 ONLY if the conditional zone (zone 7 in
zone trigger mode) is triggered (armed).
If [N], always reports alarms on zone 5.
Enables alarm reporting for zone 6.
If [N], skip to Prompt 63: "Enable Zn7."
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
UL/ULC: V+ must be set as inverted and V– as
non-inverted.
Inverts the alarm and normal states of the zone 6 trigger;
otherwise uses normal input signal.
Enables restore reporting for zone 6.
UL/ULC: Must be set to "Y."
Defines the reporting delay in seconds for zone 6.
UL/ULC: Must be set to "00."
Reports alarms on zone 6 ONLY if the conditional zone (zone 7 in
zone trigger mode) is triggered (armed).
If [N], always reports alarms on zone 6.
Enables alarm reporting for zone 7.
If [N], skip to Prompt 71: "Use DHCP."
32