PROMPTS
Telco Zone
32
(0)_
Open/Close Zone
33
(0)_
Zn1 Trigger Type
34
(V+)_
Restore Zn1 Y/N
35
(Y)_
Delay Zn1 (secs)
36
(00)_
Rpt Zn1 ONLY if
37
Armed (N)_
Invert Zn2 Y/N
38
(N)_
Restore Zn2 Y/N
39
(Y)_
Delay Zn2 (secs)
40
(00)_
Rpt Zn2 ONLY if
41
Armed (N)_
If Lynx Panic is enabled, then skip to Prompt 46: "Rpt Zn3 ONLY if Armed."
Zn3 Trigger Type
42
(V+)_
Invert Zn3 Y/N
43
(N)_
Restore Zn3 Y/N
44
(Y)_
Delay Zn3 (secs)
45
(00)
OPTIONS
Zone Trig: [3-7]
[0] = not used
Zone Trig: [3-7]
[0] = not used
 (V+)
 (V–)
 (EOLR)
[Y], [N]
[01-15]
[00] = no delay
[Y], [N]
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
[Y], [N]
 (V+)
 (V–)
 (EOLR)
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
Section 3: Programming the Communicator
See Important Information Regarding Zone Input Options on
previous page.
Enter the zone number to be used for Telco line fault reports.
This zone assignment must be unique from the open/close zone
selected in Prompt 33.
Zone Trigger Mode: If any zone is programmed for "report only if
armed," zone 7 cannot be used. If Lynx Panic is enabled,
zone 3 cannot be used.
NOTE: Connect the Telco line fault output (or relay output
programmed for "Telco line fault") to the Telco zone.
Enter the zone number to be used for open/close (arm/disarm)
reports.
This zone assignment must be unique from the Telco zone
selected in Prompt 32.
Zone Trigger Mode: If any zone is programmed for "report only if
armed," zone 7 cannot be used as an open/close zone. If
Lynx Panic is enabled, zone 3 cannot be used.
NOTE: Connect an open/close (arm/disarm) trigger (or relay
output) from the control panel to the open/close zone.
Selects the triggering method for this zone input.
Press the [space] key to scroll through the choices.
UL/UL: V+ must be set as inverted and V– as
non-inverted.
Enables restore reporting for zone 1.
UL/ULC: Must be set to "Y."
Defines the reporting delay in seconds for
zone 1.
UL/ULC: Must be set to "00."
Report alarms on zone 1 ONLY if the conditional zone (zone 7 in
zone trigger mode) is triggered (armed).
If [N], always reports alarms on zone 1.
Inverts the alarm and normal states of the zone 2 trigger;
otherwise uses normal input signal.
Enables restore reporting for zone 2.
UL/ULC: Must be set to "Y."
Defines the reporting delay in seconds for zone 2.
UL/ULC: Must be set to "00."
Reports alarms on zone 2 ONLY if the conditional zone (zone 7 in
zone trigger mode) is triggered (armed).
If [N], always reports alarms on zone 2.
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
UL/ULC: V+ must be set as inverted and V– as
non-inverted.
Inverts the alarm and normal states of the zone 3 trigger;
otherwise uses normal input signal.
Enables restore reporting for zone 3.
UL/ULC: Must be set to "Y."
Defines the reporting delay in seconds for zone 3.
UL/ULC: Must be set to "00."