Ecp Status Codes - Honeywell IntelliPath Series Installation And Setup Manual

Internet and cellular communicator
Hide thumbs Also See for IntelliPath Series:
Table of Contents

Advertisement

PROMPTS
IP Connection
51
(Present)
Review? Y/N
52

ECP Status Codes

When the communicator is configured for ECP mode, it sends status messages to the control
panels for battery, power, tamper, and network connectivity failures. Some of the control panels
(e.g., VISTA-10P, VISTA-15P and VISTA-20P Series) display these on the keypad as "LngRng
Radio" followed by a 4-digit code (listed in the table below). In addition, the Contact ID codes
(listed in Appendix B) for these conditions are sent to the central station by the communicator.
UL/ULC
STATUS CODE
0000
0880
4005
000F
0019
0400
0C80
0C8F
08E0
3000
8000
0060
OPTIONS
This prompt appears only if comm. path is set to IP & Cell.
 Present
Press the [space] key to toggle between the options. Press [ENTER] to
 Auto Detect
select the configuration.
If "Present" is chosen, it is assumed that an IP is connected to the
device. If it is not detected, a Primary Comm Path Failure message will
be delivered after the programmed fault time expires.
If "Auto Detect" is chosen, the device will always try to use IP to
communicate but it will not generate a Primary Comm Path Failure
unless it previously detected the presence of IP. As soon as the
presence of IP is detected, a Primary Comm Path Restore message is
generated and the value of IP Connectivity programming parameter is
changed from "Auto Detect" to "Detected".
From this point on, the software expects connectivity. The auto detect
logic will resume only when the parameter is changed back to "Auto
Detect".
Reviewing Programming Mode Entries
[Y] = review
To review the programming options (to ensure that the correct entries
[N] = exit
have been made), press [Y]. The programming prompts are displayed
again. Use the up/down arrow keys to scroll through the program fields
without changing any of the values. If a value requires change, simply
type in the correct value. When the last field is displayed, the
"REVIEW?" prompt again appears.
To exit the programming mode, press [N] in response to the
"REVIEW?" prompt, and refer to Exiting Programming Mode at the end
of this section.
The information in the following table is based on the VISTA-20 which has not been
evaluated with this communicator.
Table 3-3. Common ECP Keypad Display Status Codes
Control panel lost communication with communicator.
Communicator tamper detected (cover removed).
Communicator has lost contact with AlarmNet.
Communicator is not registered; account not activated.
Communicator shutdown.
Communicator power on / reset AND the control panel lost communications with
communicator.
Communicator power on / reset AND tamper detected.
Communicator power on/ reset AND tamper detected AND not registered.
Communicator tamper detected and communicator battery low.
Primary power loss (will only be displayed in conjunction with another event).
Battery charger failure (will only be displayed in conjunction with another event).
Low battery (will only be displayed in conjunction with another event).
Section 3: Programming the Communicator
DESCRIPTION
DESCRIPTION
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intellipath lte-ivIntellipath lte-iaIntellipath lte-ic

Table of Contents