When all wiring is completed, attach the case front. Position the top first, then press the bottom
section until it snaps in place. Secure bottom using the supplied cover screw.

Wiring the Communicator

UL
Installation must be in accordance with; the National Electrical Code, UL681 Installation and
Classification for Burglary and Hold-Up Alarm Systems, and UL827 for Central-Station Alarm Services.
The communicator must be connected to a UL Listed dry contact or voltage trigger outputs of a UL
Listed compatible control panel.
All interconnecting wires between the UL Listed control panel and the communicator must be less
than 3 feet in length contained in the same room. All interconnecting wiring must be installed in rigid
or EMT (where exposed on interior walls) or in flexible metal tubing if run in the walls or ceiling.
A UL listed control panel must monitor the radio fault output of the communicator. Premises openings
and closings should be sent via the UL listed control panel.
ULC
For ULC Commercial Fire and Burglary installations, only use the ULC wiring specified in Zone Trigger
Mode or the "Power Connections and Options" topic.

Wiring for ECP

Most Honeywell ADEMCO control panels support ECP data communication, (e.g., VISTA-15P,
VISTA-20P, VISTA-128BPT and VISTA-128FBPT). However, there are some panels that do not.
Check the Installation and Setup Guide for the control panel you are using to see if it supports
ECP communication.
Connect the communicator to a compatible Honeywell VISTA control panel's ECP terminals, in
parallel with keypads and other peripheral devices such as RF receiver, VIP module, etc. Wire
length/gauge limitations are the same for the communicator as they are for keypads and other
peripheral devices. To wire the communicator for ECP, see the figure below and make the
following connections:
RED
+12V AUX
BLK
GND
YEL
DATA OUT
GRN
DATA IN
VISTA CONTROL PANEL
Wiring a VISTA for ECP Mode
TRANSFORMER
TB1
1
AC INPUT 1
AC INPUT 2
2
ECP (+) VOLTAGE INPUT
3
GND
4
5
ECP DATA IN
ECP DATA OUT
6
COMMUNICATIONS
MODULE
10
BATTERY
J1