Wiring For Ecp, 4204 And Two-4204 Modes; Wiring For Zone Trigger Mode - Honeywell AlarmNet GSMHS Installation And Setup Manual

High security gsm cellular communicator
Table of Contents

Advertisement

The Telco line fault monitor should utilize either zone 6 or zone 7 on the GSMHS. When
programming the GSMHS ensure the following programming is accomplished. The example
below is for Zone 6.
Programming Prompt
Enable Zn6
Zn6 Trigger Type
Invert Zn6
Restore Zn6
Delay Zn6
Rpt Zn6 ONLY if Armed
For ECP and 4204 modes, the line fault monitor should be connected to a control panel zone.

Wiring for ECP, 4204 and Two-4204 Modes

Most Honeywell ADEMCO control panels support LRR-ECP data communication, (e.g.,
VISTA-10P, VISTA-15P, VISTA-20P, VISTA-128BP and VISTA-128FBP). However, there
are some panels that do not. Check the Installation and Setup Guide for the control panel
you are using to see if it supports ECP communication.
Connect the GSMHS to a compatible Honeywell VISTA control panel's ECP terminals, in
parallel with keypads and other peripheral devices such as RF receiver, VIP module, etc.
Wire length/gauge limitations are the same for the module as they are for keypads and other
peripheral devices. To wire the module for ECP or 4204 modes, see Figure 2-2 and make the
following connections:
VISTA CONTROL PANEL
Figure 2-2. Wiring a VISTA for ECP Mode or 4204 Modes

Wiring for Zone Trigger Mode

To trip a zone on the GSMHS in V+ trigger mode, the positive triggering voltage from the
control panel must be within 6V-12V. UL Installations: Use inverted mode.
Trigger levels above this range may cause permanent damage to the unit.
Trigger levels below this range result in unreliable operation.
To trip a zone on the GSMHS in V- trigger mode, the negative triggering voltage must be less
than 1.0V.
Connect a wire from the triggering source (bell output, voltage trigger, etc.) of the control
panel to the zone input of the module, and connect a common ground between the module
and control panel. NOTE: This mode has not been evaluated by UL.
Examples of zone connections follow:
Setting
[Y]
[V+]
[Y]
[Y]
[00]
[N]
TRANSFORMER
RED
+12V AUX
BLK
GND
YEL
DATA OUT
GRN
DATA IN
Section 2: Mounting and Wiring
TB1
1
AC INPUT 1
AC INPUT 2
2
ECP (+) VOLTAGE INPUT
3
GND
4
5
ECP DATA IN
ECP DATA OUT
6
J1
COMMUNICATIONS
MODULE
BATTERY
2-3