2-Post Rack Mount Installation
Mid-Bracket to Rail 3 Inch Flush Mount Assembly
To secure the mid-bracket to the rail for a 3 inch post flush mount assembly:
1.
Align the mid-bracket (callout 2) with the four rail holes closest to the rail ear (callout 3) as
shown in
2.
Insert and secure the four screws (callout 1) from the rack mount extension assembly for both
rails
Figure C-8
1
Four screws from extension rack assembly
2
Mid-bracket
Mid-Bracket to Rail 7.25 Inch Flush Mount or Mid-Mount Assembly
To secure the mid-bracket to the rail for a 7.25 inch post flush mount assembly:
1.
Align the mid-bracket (callout 2) with the four rail slots as shown in
2.
Insert and secure the four screws (callout 1) from the rack mount extension assembly, allowing
some play to adjust the mid-bracket position within the slot space when securing the
assembly to the rack post
3.
If the assembly will be used in a mid-mount configuration, insert a cage nut (callout 4) that
comes with the kit in the rail ear square opening (callout 3)
4.
Repeat steps 1–3 for the other rail
C-10 Optional Rack Mount Rail Kit Installation
Note: If you are installing the rack mount rail in a flush mount 7.25 inch rack post or a mid-mount
configuration, proceed to
"Mid-Bracket to Rail 7.25 Inch Flush Mount or Mid-Mount
page C-10, otherwise continue here.
Figure C-8
for both rails

Securing Mid-Bracket to Rail 3 Inch Flush Mount

3
Rail ear
Assembly" on
Figure C-9
on page C-11