Securing The 7100G-Series Chassis To The Rack; Securing Mid-Mount Rail Assembly - Enterasys 7100G Series Hardware Installation Manual

Table of Contents

Advertisement

Figure C-11
1
Rack appropriate screws or fasteners (4)

Securing the 7100G-Series Chassis to the Rack

To secure the 7100G-Series chassis to the rack:
1.
Slide the chassis onto the rail assembly until the chassis adapter plate ears meet the rail
assembly ears. See
2.
For a flush mount rail assembly configuration, secure each side of the chassis using a screw or
fastener appropriate to your rack that you provide.
3.
For a mid-mount rail assembly configuration, secure each side of the chassis using a black,
10-32 screw that comes with the rack mount kit. These screws are screwed into the cage nut
installed in the square rail ear opening as described in Step 3 of section
7.25 Inch Flush Mount or Mid-Mount

Securing Mid-Mount Rail Assembly

Figure C-12
on page C-14.
2
Cage nuts (2)
Assembly" on page C-10.
Enterasys 7100G-Series Hardware Installation Guide C-13
2-Post Rack Mount Installation
"Mid-Bracket to Rail