Figure 96
80
9

Operation / Tying

9.1

BALERCONTROL E control box

9.1.1
The control box
The BALERCONTROL E control box has the following functions
and displays (Figure 96):
Item Part
1
LED, green
2
LED, red
3
LED, yellow
4
LED, yellow
5
Button
6
Button
7
Button
8
Display,
illuminated
9
acoustic buzzer
(back side)
The following tying modes can be selected – dependent on the
type and version of the machine:
• Manual net tying
• Automatic net tying
• manual twine tying
• automatic twine tying
Meaning
Power supply correct
Preset bale diameter reached or exceeded
automatic net tying selected. (flashes
when net coupling is in operation)
Automatic twine tying selected. (Flashes
when twine motor is in operation)
Toggling between manual and automatic
tying (see chapter 9.1.2 Trigger tying
(BALERCONTROL E))
hold for 5 sec:
resetting the bale counter
(TAZ)
Manual activation of net tying
Manual activation of twine tying
Top line:
Cumulative counter cannot be deleted
Bottom line:
Day counter, can be deleted
Preset bale diameter reached