106
Caution!
Never use for cleaning: Tri, Per, methanol, acetone or other
polar, organic solvents.
Cleaning:
once per year: clean complete lubricating pump.
Regulating the flow rate:
Caution!
To avoid damage to the lubricating pump and the roller chains
or to the machine: The flow rate of the lubricating pump
correctly set in the factory must not be changed.
If certain cases require adjustment of the flow rate: such work
may be carried out only by trained and instructed service
personnel on the basis of the service information provided by
Welger.
11.9

Winter pause

Prior to a winter pause:
Place the machine on an even surface to avoid frame
tension.
Unthread twine, unthread net.
Remove twine, net and straw remains from the machine.
Disconnect control box from the machine (pull plug).
Keep control box dry and at room temperature.
Remove, grind and reinstall cutting device knives.
Grease tying mechanism.
Thoroughly lubricate all bearings.
Slightly grease the surface of the baling chamber by means
of a lubricant degrading neither the environment nor the
fodder ( e.g. rape oil).
Check and - if necessary - adjust air pressure of tires (11.7
Tire air pressure).
WELGER RP 405 • RP 435