3.16 Alarm Response

The Alarm Response function controls how certain activations are to perform.
Silent 1st Alarm
If this function is selected as 'confirmed', then the first alarm to activate on the system will be
silent, but only if another input activates (i.e. a confirmed alarm) then the alarm will activate and
the alarm tones will be heard. This option is only valid once the system has been set for 3
minutes and not if the entry time has started.
Disable Confirm On Entry
To comply with BS8243 clauses 6.4.3 and 6.4.4, this option should be set to YES to disable
confirmation once the entry procedure has started. For use with BS8243 option 6.4.5, this
option should be 'No'. If 'Disable Confirm On Entry' is set to YES this option will disable ALL
confirmation signals on entry. If NO the confirmation signals are enabled on expiry of entry time.
Alarm Starts / Stops (Alarm Responses)
There are 4 different 'Alarm Responses' that can be programmed:
[0] Keypads: If an alarm occurs, the keypad sounder will activate.
[1] Internal Sounders: If an alarm occurs, the internal sounder will activate.
[2] Bells Only: If an alarm occurs, the external sounders will activate.
[3] Signal Digi: If an alarm occurs, the digi will communicate.
[4] Confirm: If an confirmed alarm occurs.
If the Alarm Response for Area A is programmed as 'Start At' "Keypads" and 'Stop at' "Bells
Only" then it will take 15 seconds to go through each alarm responses before stopping at "Bells
Only".
If the Alarm Response is programmed as 'Start At' "Signal Digi" and 'Stop At' "Confirm", all
keypads, internal sounders and bells only will activate the same time as 'Signal Digi' and all will
stop when there is a 'Confirmed Alarm'.
The Enforcer can operate on a combined Area basis, for example if both Areas 'A' and 'B' are set;
you may want the process of the alarm responses to change. Therefore The 'If Areas set' section
of this function should be used and select the desired Areas and the Alarm Responses.
Alarm Responses Programming
1. Press or to scroll to 'ALARM RESPONSES'. Press .
2. 'Silent 1st Alarm' will be displayed. Press [ or ] to enable or
disable and press .
3. 'Disable Confirm on Entry' will be displayed. Press [ or ] to
enable or disable and press .
4. 'Area A start at' will be displayed. Press [ or ] to select the
alarm responses and press . Repeat for all alarm notifications.
5. The Engineer menu will be displayed.

3.17 Set Up Downloading

If required, the Enforcer can be programmed remotely, or directly via a PC/Laptop.
To upload/download remotely, a communications module must be installed.
To upload/download directly, an RS232 must be used and connected directly to the Enforcer.
Set Up Downloading Programming: Cloud
1. Press or to scroll to 'SET UP DOWNLOADING?'. Press
.
2. 'Download By' : Use [ or ] to scroll to 'Cloud'. Press .
3. The SYSTEM ID will be displayed will be displayed. Press .
4. Use [ or ] to select either Normal or High Security Level.
NOTE: If High is selected, encrypted keys will need to be created.
Press .
5. Enter a System Password. Press (NOTE: This is required)
Enforcer: Programming Manual
Page: 28
ALARM RESPONSE?
Silent 1st Alarm
Never
Disable Confirm
On Entry. No [0]
SET UP
DOWNLOADING?
Download by
Cloud
SYSTEM ID
AAABBBCCC
[0]