Common Lobby
If 'Yes', this will automatically prioritise the exit modes for each area:
(0 = Timed, 1 = Final Door, 2 = Timed/Final Door, 3 = PTS). This option is only relevant when
Final Door option is used on a system with different areas using a common lobby.
EXAMPLE: If Area C is selected as the 'Final Door' setting mode and the rest of the areas are
selected as 'Timed', then because 'Final Door' is higher priority, the users of every individual area
must follow the 'Final Door' route to the exit - making this door a 'common for all areas'. If set to
'NO' the exit modes will be individually programmable to each area.
Flexi Unset
When enabled, this setting will allow users to select which areas they unset (from the
areas that they have been permitted to unset.)
2 Key HU:
If the 1 and 7 keys are pressed and held together for a period of time (programmed in the
keypad menu, see page: 13), a 'Hold Up' will occur.
If 'NONE', the keys are disabled. If 'SILENT', a 'Silent Hold Up' will be signaled. If 'Bells Only',
any external sounder will activate but NO signals will be sent. If 'BOTH', any external sounder
will activate and a signal will be sent using a Digi 1200 (PSTN),Digi-1200/Voice Digi GPRS, Digi
LAN or Digi Wi-Fi module.
Tag Opens Doors
This function is only be used in conjunction with a reader being programmed as 'Entry Control' is
in 'ASSIGN KEYPADS/READERS' (see page: 12).
If 'YES' the 'Entry Control' readers will control the setting/unsetting and the doors. If 'NO' the
Entry Control readers will control the setting/unsetting only.
Fire Key Enable
If 'YES' the fire key will be enabled on the Enforcer keypad.
Set With Polling Fault
If 'YES' the Enforcer will set the system if there is a wireless polling fault.
If 'NO' the user will not be able to set the Enforcer with a polling fault. The Enforcer will display a
fault and the arming procedure will be stopped. The input causing the poll fault can be identified
in the event log.
Fob Unset Entry
If 'YES' any wireless keyfobs learnt will only be able to unset the Enforcer once the entry time
time has been activated. If 'NO' any wireless keyfobs learnt will always be able to set and unset
the Enforcer.
Wireless Bell Supervision
If 'YES' then the wireless external sounder (DELTABELL-WE) will go into alarm if it can no longer
communicate with the Enforcer.
Download if Set
If 'YES' any upload/download procedures will be possible on the InSite software regardless of the
set/unset status of the Enforcer.
UDL or Cloud Priority
By default this is set to 'high' meaning that UDL or Cloud signalling will take priority over ARC
signalling events to maintain a smooth cloud connection. If the system is graded then this setting
will default to 'low' so that UDL or Cloud connections cannot delay ARC signalling events.
Site Options Programming
1. Press or to scroll to 'SITE OPTIONS'. Press .
2. 'Set With Fault' will be displayed. Use [ or ] to
enable/disable each option and press . Repeat for all
functions. The engineer menu will be displayed once all
functions have finished.
Enforcer: Programming Manual
Page: 19
SITE OPTIONS?
Set With Fault