Controls
Operating altitude
Permitted air humidity
Degree of protection
Protection class
Overvoltage category
Contamination level
Mechanical tests
Vibration resistance acc. to DIN EN 60068-2-6
Shock test acc. to DIN EN 60068-2-27
Broadband noise acc. to DIN EN 60068-2-64
Electrostatic discharge
ESD resistance acc. to DIN EN 61131-2
Test voltage
●
①
The vibration stress specifications assume the use of industrial-suited RJ45 plug connec-
tions. The "Industrial RJ45 plug" of the company Yamaichi is recommended (Y-Con-
Plug-41). The cables are available as accessories (RKB0020). To protect against vibration,
secure the cables with a short distance (< 20 cm). The USB interfaces XF30 and XF31
may only be used up to a vibration stress of 1 g.
Tab. 6-1: Ambient conditions
NOTICE
The ambient air must not contain acids, alkaline solutions, corrosive agents,
●
salts, metal vapors and other electrically conductive contaminants in high
concentrations
Housing and installation compartments must at least comply with the degree
●
of protection IP 54 according to DIN EN 60529
NOTICE
Due to the risk of corrosion, avoid sulphurous gases (e.g. sulphur dioxide (SO
and hydrogen suphide (H
DOK-CONTRL -IC*XM2*****-IT03-EN-P
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Up to 4,700 m above sea level acc. to DIN 60204
5 % to 95 % acc. to DIN EN 61131-2, no conden-
sation
IP20 acc. to DIN EN 60 529
III, DIN EN 61010-2-201
2
2, no condensation allowed
Oscillations, sinusoidal in all three axes
①
5 Hz - 9 Hz with 3.5 mm amplitude
9 Hz -150 Hz with 5 g peak acceleration
Shock stress: Shock resistance in all three axes,
11 ms semi-sinusoidal 30 g
5-20-150 Hz with 0.572 g, 5 h per axis
Criterion B
8 kV for air discharge
6 kV for contact discharge
Failure of the product due to contaminated air
Defective product due to gases jeopardizing
functions
S)). The product is not resistant against these gases.
2
Bosch Rexroth AG
Ambient conditions
2
7/61
)