Installing/Mounting
4.2 Installation procedure
4.2.6
Install calibration weights
Note
When using flat bar weights, ensure adequate base-bar weight clearance before adding
calibration weights. When using the round bar weight, the bar weight is an integrated part of
the base-bar.
①
②
1. Turn the crank handle, or use the control buttons, until the lifting arms are fully lowered.
2. Place the base-bar weight into position on the calibration weight supports of the Milltronics
belt scale.
20
base-bar weight applied
lifting arms lowered
Milltronics MWL Weight Lifter
Operating Instructions, 11/2011, 7ML19985CR03-03