10.2 Installation drawings
2. Remove the idler.
3. Remove the two socket-head cap-screws that secure the calibration weight bar, then remove
the calibration weight bar from the dynamic beam of the belt scale.
4. Clamp the bottom of the idler support angle-brackets to the dynamic beam, using two C-
clamps.
5. Remove the four socket head bolts that secure the idler support angle-brackets.
6. Mount the new calibration weight brackets using the same holes as the idler support angle
brackets. Use the new bolts and nuts supplied with the calibration weight brackets, and hand-
tighten the nuts.
7. Align the new calibration weight brackets with each other vertically and horizontally.
54
idler removed
shipping stops in vertical position
calibration weight bar removed
calibration weight brackets
bolts (step 6)
angle-bracket
dynamic beam
C-clamp (customer supplied)
calibration weight bracket
Milltronics MWL Weight Lifter
Operating Instructions, 11/2011, 7ML19985CR03-03