Operation (Electronic Version); Electronic Control Panel; Local Mode - Siemens Milltronics MWL Weight Lifter Operating Instructions Manual

Belt scales weight lifler
Table of Contents

Advertisement

7.2

Operation (electronic version)

7.2.1

Electronic control panel

The electronic version of MWL uses an AC gearmotor to lift and lower the belt scale calibration
weights. The motor is operated from an electrical panel with the following controls:
● Operator key switch: OFF, LOC (local), REM (remote)
● UP pushbutton with green indicator
● DOWN pushbutton with red indicator
● EMERGENCY STOP pushbutton
Note
Motor overload protection
 Should the motor run up against a physical stop, the internal overload relay will trip and
the motor will stop, preventing damage.
 If the proximity sensor is not activated within a specified time, the motor will be
deactivated and the brake applied. If this happens, check for mechanical restrictions and
malfunctioning sensors.
7.2.2

Local mode

Applying calibration weights
1. Turn the key switch to the LOC position. The Local Relay coil will be energized providing an
enable signal to the LOGO relay, releasing the brake and allowing the motor to move freely.
2. Push the DOWN button. The MWL will move down until the DOWN sensor activates,
disabling the reversing contactor and bringing the motor to a rest position.
While the MWL is moving, the red DOWN indicator will blink. Once it stops, the indicator will
remain on.
3. Refer to the manuals for the Milltronics Belt Scale and Integrator, to perform the appropriate
calibration procedures.
Milltronics MWL Weight Lifter
Operating Instructions, 11/2011, 7ML19985CR03-03
7.2 Operation (electronic version)
Operation
39