10.2.5.1

Retrofitting an MSI or MMI belt scale

Two new calibration weight brackets are required with the MWL to replace the existing
calibration weight bar. New bolts are supplied, but you will also need a C-clamp, metric Allen
keys, and metric wrenches.
CAUTION
Take care to protect the load cells from impact or prying forces during installation of the
new calibration weight brackets.
1. Rotate the shipping stops on the MSI into a vertical position, and tighten screws A to secure
the stops in place. This will help to protect the load cells from damage while the calibration
weight brackets are being installed.
Milltronics MWL Weight Lifter
Operating Instructions, 11/2011, 7ML19985CR03-03
screws A
screws B
shipping stop in free position
Dimension drawings
10.2 Installation drawings
53