8. Tighten the nuts and bolts firmly to secure all four brackets.
Torque value = 54.6 Nm (40 ft-lbs).
9. Remove the C-clamps.
10. Re-install the idler and check idler alignment as described in the belt scale operating
instructions.
11. Free the weight mechanism: loosen screws A and rotate the 2 shipping stops inward and
down, over screws B (see step 1). Tighten screws A to secure them in place.