Installing/Mounting
4.2 Installation procedure
Recheck crank body alignment
1. After shimming, raise and lower the lifting arms to check whether there is any binding or
hesitation. If there is, repeat the alignment procedure (Page 19).
2. Raise the lifting arms again and check the clearance between the underside of the base-bar
weight and the top surface of the calibration weight support.
3. Repeat the shimming procedure until the lifting arms raise the calibration weights at least 10
mm (0.38") above the calibration weight supports.
4. Tighten the torque shaft bolts and the crank-body mounting bolts, then recheck all
clearances.
The MWL installation is now complete.
26
10 mm (0.38") minimum clearance
top surface of calibration weight support
lifting arm raised
underside of base-bar weight
Milltronics MWL Weight Lifter