2.4 Checking voltage level
- Detach connector from regulator and connect Tester (DC
20 V), as follows:
- Terminal (+) of tester
- Terminal (-) of Tester
- Turn key "ON".
- Value read must be approximately 12 Volts.
Regulator is not grounded.
Put black cable (Pin2) in working order (see wiring
diagram).
2.5 Checking regulator (test "B")
- Provide jumper between brown cable (Pin5) and blue
cable (Pin3) of connector (A).
- Turn key "ON".
- Operate right/left turn indicator switch to make sure that
indicators come on and remain steadily lit.
Replace voltage regulator.
NOTE:
if grounding (Pin2) or power supply (Pin3) are lacking,
the regulator will cause malfunctioning of the lighting
circuit and battery recharging system, as well as
disengagement of the throttle.
30
PAGE
SECTION 2
B
- TROUBLESHOOTING
ELECTRIC SYSTEM TROUBLESHOOTING
Signalling system
Blue cable (Pin3).
Black cable (Pin2).
COMPLIANT
INDICATORS ARE
ALWAYS ON
SECTION 2
NOT COMPLIANT
Blue cable between key switch and
regulator connector (Pin3) is interrup-
ted. Repair (see wiring diagram).
INDICATORS DO NOT COME ON
Repeat all checks (tests have not been
performed correctly).