Malaguti CIAK MASTER 50-4T Electric System Troubleshooting page 15

Table of Contents

Advertisement

If the battery cannot be charged, check:
1.
Fuse (10A)
2.
Battery
3.
Charging voltage
4.
Stator coil resistance
5.
Charging system wiring
1. Fuse (10 A)
- See "Checking switches" section (page 12).
2. Battery
- Remove battery and connect Tester (DC 20 V), as follows:
- Terminal (+) of Tester
- Terminal (-) of Tester
- If voltage level is lower than 12.4 V, recharge using a suitable battery charger.
- After charging the battery, do not use it for approximately 30 minutes; now measure voltage level again.
- 12.8 V or more
- 12.5 V
Battery needs to be recharged.
- 12.0 V
Replace battery.
3. Check charging voltage (use a charged battery)
- Connect Tester (DC 20 V) to battery as follows:
- Terminal (+) of Tester
- Terminal (-) of Tester
- Run engine at approx. 4000 RPM.
- The voltage measured should be: 14 ÷ 14.5 Volts.
10.05
ISSUE
B
ELECTRIC SYSTEM TROUBLESHOOTING
Charging System
OK
Battery (+) pole.
Battery (-) pole.
Battery is charged.
BATTERY OK
Battery (+) pole.
Battery (-) pole.
NOT COMPLIANT
- TROUBLESHOOTING
N
+
COMPLIANT
- The recharging circuit is working.
SECTION 2
B
CHAPTER
17
PAGE
SECTION 2