Malaguti CIAK MASTER 50-4T Electric System Troubleshooting page 30

Table of Contents

Advertisement

B
CHAPTER
3.4 Checking voltage level
- Connect Tester (DC 20 V) to horn (3), as follows:
- Terminal (+) of tester
- Terminal (-) of tester
- Turn key "ON".
- Value read must be 12 V.
- Orange cable between left hand switch and horn is
interrupted.
- Repair.
- See "Wiring Diagram".
4. FUEL LEVEL INDICATOR IS NOT WORKING
4.1 Fuel probe
- Detach connector of probe.
- Provide jumper (1) between white/green cable and black
cable of three-way connector of wiring.
INDICATOR HAND ON
INSTRUMENT BOARD
DOES NOT MOVE
32
PAGE
SECTION 2
B
- TROUBLESHOOTING
ELECTRIC SYSTEM TROUBLESHOOTING
Signalling system
Blue cable (1).
Chassis grounding (2).
COMPLIANT
SECTION 2
1
BL
AR
3
NOT COMPLIANT
- Blue cable between key switch and
horn is interrupted.
- Repair (see wiring diagram).
1
INDICATOR HAND IS POINTING TO "FULL" (1)
- Fuel probe is faulty.
- Replace.
2
10.05
ISSUE

Hide quick links: