Month Preventive Maintenance - Kodak X-Omat 270 RA PROCESSOR Service Manual

Hide thumbs Also See for X-Omat 270 RA PROCESSOR:
Table of Contents

Advertisement

3 Month Preventive Maintenance

[1] De-energize the PROCESSOR.
[2] Open the FIXER and DEVELOPER DRAIN VALVES to drain the solutions from the PROCESSOR.
[3] Remove the following parts:
a. WET SECTION COVER
b. WATER DISCONNECT and WATER RESERVOIR or YOKE
c. EVAPORATION COVERS
d. all CROSSOVERS
e. DRYER RACK
f. WASH RACK
Caution
To prevent contamination of the developer and fixer solutions when you remove the FIXER RACK and the
DEVELOPER RACK, place the SPLASH GUARD between the DEVELOPER TANK and the FIXER TANK. Use
the DRIP TRAY whenever you remove or installation the RACKS.
[4] Install the SPLASH GUARD between the DEVELOPER TANK and the FIXER TANK.
[5] Remove the following parts:
a. FIXER RACK
b. SPLASH GUARD
c. DEVELOPER RACK
Warning
• Carefully follow all safety precautions and directions included with the Kodak FIXER/WASH SYSTEM
CLEANER and Kodak DEVELOPER SYSTEM CLEANER AND NEUTRALIZER.
• The RACKS in the PROCESSOR have hollow ROLLERS. Use the instructions for cleaning RACKS with
hollow ROLLERS. Do not immerse RACKS with hollow ROLLERS in SYSTEM CLEANER. SYSTEM
CLEANER that remains inside the ROLLERS will contaminate the processing solutions.
• When circulating SYSTEM CLEANER or water through the recirculation system, energize the developer
COOLING SOLENOID and the RECIRCULATION PUMP using the PORTABLE COMPUTER. See the
Diagnostics Manual. Otherwise the following may occur:
– The effectiveness of the DEVELOPER SYSTEM CLEANER AND NEUTRALIZER will be greatly
reduced because of the developer remaining in the HEAT EXCHANGER.
– The DEVELOPER SYSTEM CLEANER AND NEUTRALIZER remaining in the HEAT EXCHANGER
will contaminate the new developer when the PROCESSOR is returned to operation.
[6] Clean the DEVELOPER RACK and the DEVELOPER TANK with Kodak DEVELOPER SYSTEM
CLEANER AND NEUTRALIZER, CAT No. 843 4615.
[7] Clean the FIXER RACK, the WASH RACK, and the FIXER TANK with Kodak FIXER/WASH SYSTEM
CLEANER, CAT No. 139 5110.
[8] Clean the WASH TANK with Kodak FIXER/WASH SYSTEM CLEANER or, if biological growth exists, with
a 10% solution of chlorine bleach.
[9] If necessary, clean the LEVEL SENSOR PROBES with the correct SYSTEM CLEANER.
SM3058-3 – May 1996
Preventive Maintenance
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

X-omat multiloader 300

Table of Contents