HPE 800W Flex Slot Titanium Hot-plug Low Halogen Power Supply on page 120
•
HPE 800W Flex Slot Universal Hot-plug Low Halogen Power Supply on page 121
For detailed power supply specifications, see the QuickSpecs on the Hewlett Packard Enterprise
website.
HPE 500W Low Halogen Non-hot-plug Power Supply
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
Rated steady-state power
Maximum peak power
HPE 500W Flex Slot Platinum Hot-plug Low Halogen Power Supply
Specification
Input requirements
Rated input voltage
Rated input frequency
118
Specifications
Value
—
100 VAC to 240 VAC
240 VDC for China only
50 Hz to 60 Hz
5.8 A at 100 VAC
2.3 A at 240 VAC
2.7 A at 240 VDC for China only
578 W at 100 VAC
557 W at 240 VAC
1953 at 100 VAC
1882 at 240 VAC
—
500 W at 100 VAC to 240 VAC input
500 W at 240 VDC input for China only
500 W at 100 VAC to 240 VAC input
500 W at 240 VDC input for China only
Value
—
100 VAC to 240 VAC
240 VDC for China only
50 Hz to 60 Hz
Not applicable to 240 VDC
Table Continued