Nvme Ssd Button Actions - HPE ProLiant DL160 Gen10 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL160 Gen10:
Table of Contents

Advertisement

Item LED
4
Do not
remove
5
Power

NVMe SSD button actions

Status
Definition
The drive is doing one of the following:
Flashing green
Rebuilding
Performing a RAID migration
Performing a stripe size migration
Performing a capacity expansion
Performing a logical drive extension
Erasing
Flashing amber/
The drive is a member of one or more logical drives and predicts the
green
drive will fail.
Flashing amber The drive is not configured and predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID controller.
Solid white
Do not remove the drive. The drive must be ejected from the PCIe bus
prior to removal.
Flashing white
The drive ejection request is pending.
Off
The drive has been ejected.
Solid green
Do not remove the drive. The drive must be ejected from the PCIe bus
prior to removal.
Flashing green
The drive ejection request is pending.
Off
The drive has been ejected.
Component identification
101

Advertisement

Table of Contents
loading