Specifications
Environmental specifications
Specification
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1000 ft) to 3050 m
(10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The
upper limit and rate of change might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
•
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of
1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m
(10,000 ft).
•
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F
per every 410 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft).
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise
website.
Mechanical specifications
Specification
Height
Depth
Width
Weight (approximate range)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
•
HPE 500W Low Halogen Non-hot-plug Power Supply on page 118
•
HPE 500W Flex Slot Platinum Hot-plug Low Halogen Power Supply on page 118
•
HPE 800W Flex Slot Platinum Hot-plug Low Halogen Power Supply on page 119
1
Value
4.29 cm (1.69 in)
61.50 cm (24.21 in)
43.46 cm (17.11 in)
10.00 kg to 16.00 kg (22.03 lb to 35.27 lb)
Value
—
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
—
8% to 90%
28°C (82.4°F), maximum wet bulb temperature
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
Specifications
117