Replacing The Pump Filter (Generation 2 Pump) - Honeywell BW GasAlertMicro 5 User Manual

Table of Contents

Advertisement

Replacing the Pump Filter (Generation 2 Pump)

To replace the Generation 2 pump filter, refer to
ing steps 1-8.
If using the auxiliary filter on the Generation 1 pump or as an
additional filtration system on the new pump module, refer to
Attaching the Auxiliary
Figure 7. Replacing the Pump Filter (Generation 2 Pump)
Find Quality Products Online at:
Figure 7.
and the follow-
Note
Filter.
GlobalTestSupply
www.
1. Deactivate the detector.
2. Remove the filter window screw.
3. Remove the filter window.
4. Remove the old filter from the filter window.
Important! Ensure the filter cavity and filter window are clean
and free of debris.
5. Insert a new filter.
6. Replace the filter window and screw.
7. Activate the detector. The detector performs a pump test
during the startup self-tests to verify the pump module is oper-
ating correctly.
8. To order additional filters, refer to
Accessories.
a Caution
Filters may need to be replaced more frequently in high
particulate areas. BW Technologies by Honeywell
recommends that the auxiliary filter be used as a
additional filtration in high particulate areas.
.com
GasAlertMicro 5/PID/IR
Installing the Pump Module
Replacement Parts and
sales@GlobalTestSupply.com
67

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bw gasalertmicro 5 irBw gasalertmicro 5 pid

Table of Contents