AT commands
Default
0

I/O settings commands

The following AT commands are I/O settings commands.

CB command

Use CB to simulate commissioning pushbutton presses in software.
Set the parameter value to the number of button presses that you want to simulate. For example,
send CB1 to perform the action of pressing the Commissioning Pushbutton once.
See
The Commissioning
See
Commissioning pushbutton
Parameter range
0 - 4
Default
N/A

D0 (DIO0/AD0)

Sets or displays the DIO0/AD0 configuration (pin 33).
Parameter range
0 - 5
Parameter
0
1
2
3
4
5
Default
1

D1 (DIO1/AD1)

Sets or displays the DIO1/AD1 configuration (pin 32).
Parameter range
0, 2 - 5
XBee® SX 868 RF Module User Guide
Pushbutton.
Description
Disabled
Commissioning Pushbutton
ADC
Digital input
Digital output, low
Digital output, high
I/O settings commands