Appendix 1 Obis Code - Landis+Gyr E650 Series 4 User Manual

Electricity meters iec/mid industrial and commercial
Table of Contents

Advertisement

94/96
Appendix 1
Object Identification System
A: Medium
[1 ... 9]
B: Channel
[1 ... 64]
C: Measured quantity
[1 ... 99]
© Landis+Gyr
OBIS code
The OBIS code (Object Identification System) is structured as follows:
A
B
C
D
M-
KK:
GG.
AA.
Defines the medium used. If only one medium is used it does not have to
be specified. The Values represent the following objects:
1 Electricity
2, 3 Not used
4 Heating costs
5 Cooling system
6 Heating system
7 Gas
8 Cold water
9 Hot water
Defines the channel number, i.e. the number of the input of a metering
equipment with several inputs for the measurement of energy of the same
or different types (e.g. in data concentrators, registration units). This
enables data from different sources to be identified. If only one channel
(only one meter) is used, it does not have to be specified.
Defines the abstract or physical data items related to the information
source concerned, e.g. active power, reactive power, apparent power,
cosj, current or voltage.
General data
Active energy
+ (import)
– (export)
Reactive energy
+
QI (quadrant I)
QII
QIII
QIV
Apparent energy
+ (import)
– (export)
Current
Voltage
Power factor
Frequency
Service data
Error message
Profile data
D000062026 en a – E650 Series 4 – ZMD400AT/CT, ZFD400AT/CT – User Manual
E
F
Value group
T
W
According to VDEW
0
∑Li 1
L1 21
2
3
4
5
6
7
8
9
10
11
12
13
14
C
F
P

Appendix 1 OBIS code

L2 41
L3 61
22
42
62
23
43
63
24
44
64
25
45
65
26
46
66
27
47
67
28
48
68
29
49
69
30
50
70
31
51
71
32
52
72
33
53
73