Landis+Gyr E650 Series 4 User Manual page 89

Electricity meters iec/mid industrial and commercial
Table of Contents

Advertisement

Maintenance
D000062026 en a – E650 Series 4 – ZMD400AT/CT, ZFD400AT/CT – User Manual
3.
Press on the latch of the plastic battery holder until it releases and then
withdraw the battery holder with the old battery.
Figure 81. Removing the battery
4.
Mark the current date on the new battery.
5.
Withdraw the old battery from the holder and insert the new battery.
6.
Push the battery holder with battery into the battery compartment until
the latch engages.
7.
Reset the battery hours counter to zero with the relevant formatted
command (see section 5.8 "Input of formatted commands") or in the
set mode (see section 5.9 "Set time and date, ID numbers, battery
time").
8.
Close the front door.
9.
Re-seal the front door.
10. Dispose of old batteries as hazardous waste in accordance with local
regulations.
Checking time-of-day and date
After inserting the battery, check the time-of-day and date without power
applied and set these values again, if necessary.
89/96
© Landis+Gyr

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zmd400atZmd400ctZfd400ctZfd400at

Table of Contents