4.5. Adapting the configuration parameters
--
When the programme is in operation mode (and not in programming mode), the parameters can be
modified according to the following procedure by means of the FTX117 console.
a) Start-up
1.
Plug the console in.
2.
Wait for the CONNECTION menu to appear.
3.
Select MASTER with the vertical arrows.
4.
The ADJUST menu appears.
5.
With the horizontal arrows, select 2 Dat then ENTER.
6.
The console is ready.
b) Variable setting
In order to force %M3, %M46, %M47 temporarily, introduce the name of the variable validated by the
ENTER key. Then type 0 or 1 followed by ENTER.
Example: %M3 – Counting the number of passage authorizations
1.
Press the %M key followed by 3 and ENTER.
2.
Type 0 or 1 followed by ENTER.
In order to definitely force %M3, %M46, %M47, introduce the variable name validated by the
ENTER key. Press the MENU key. Choose bit with the horizontal arrows and then 0
(forced to 0) or 1 (forced to 1) with the vertical arrows. Then press ENTER.
Example: %M3 – Counting the number of passage authorizations
1.
Press the %M key followed by 3 and ENTER.
1.
Press the MENU key.
2.
Choose bit with the horizontal arrows.
3.
Choose 0 or 1 with the vertical arrows.
4.
Validate with the ENTER key.
The %MW0 and %MW12 variables cannot be modified. They are respectively used to display the PNG
programming stage and the PNG cell state.
For %MW1 and %MW8, introduce the name of the variable validated by the ENTER key. Then enter
the selected value.
Example: %MW1 – Configuration of pictograms in direction A
1.
Press the %MW key followed by 1 and ENTER.
2.
Type 0 (limited management) or 1 (extended management) followed by ENTER.
Proceed as follows for the %MW4 variable (Configuration of the safety system).
1.
Press the %MW key followed by 4 and ENTER.
2.
Select Menu.
3.
Select Cnv then ENTER with the horizontal arrows, .
4.
Select Bin then ENTER with the vertical arrows.
5.
Position the cursor in order to display the X0 bit (corresponding to the CS cell).
6.
Type 0 or 1 followed by ENTER.
7.
Position the cursor in order to display the X1 bit (corresponding to the C6 cell).
8.
Type 0 or 1 followed by ENTER.
9.
Position the cursor in order to display the X2 bit (corresponding to the C7 cell).
10. Type 0 or 1 followed by ENTER.
11. Position the cursor in order to display the X3 bit (corresponding to the C13 cell).
12. Type 0 or 1 followed by ENTER.
13. Position the cursor in order to display the X4 bit (corresponding to the C14 cell).
14. Type 0 or 1 followed by ENTER.
15. Select Menu.
16. Select Cnv then ENTER with the horizontal arrows.
17. Select Dec then ENTER with the vertical arrows.
c) Adjusting the time-outs and monostables
Automatic Systems PNG38X-A3_1-04-gb-02.doc
10/12/01
p. 33/51
Need help?