General technical specifications
Article number
Weight without mounting brackets
Power supply
Brief voltage interruption in accord-
ance with Namur
Current consumption
Noise emission
Degree of protection
Degree of pollution
Quality assurance
The device should only be connected to a power supply which meets the requirements of safe
1)
extra low voltage (SELV) according to IEC/EN/DIN EN/UL 60950-1. The power supply must meet
the requirement NEC Class 2 or LPS according to the IEC/EN/DINEN/UL 60950-1.
In the event of low supply voltage, the buffer time is reduced.
2)
Electromagnetic compatibility
Immunity with regard to conducted
interference on the supply lines
Noise immunity on signal lines
Immunity to discharges of static
electricity
Immunity to RF interference
If there are voltage peaks on power supply lines, use a protective device in the form of a
varistor (MOV) UMOV = U-rated x 1.2 (BLITZDUCTOR BVT AVD 24 (918 422) or
compatible).
SINAMICS CONNECT
Operating Instructions, 10/2018, A5E45421408
6SL3255-0AG30-0AA0
Net weight: 0.258 kg
Gross weight: 0.328 kg
9 V DC to 36 V DC, no galvanic isolation
1)
≤ 5 ms buffer time at 24 V DC and full load
≤ 10 events per hour; recovery time at least 10 s
≤ 1.4 A
< 40 dB(A) according to DIN EN 27574-1
IP20 according to IEC 60529
2
In accordance with ISO 9001
± 2 kV according to IEC 61000-4-4; burst
± 1 kV according to IEC 61000-4-5; asymmetrical surge
± 1 kV according to IEC 61000-4-4; burst; length < 30 m
± 2 kV according to IEC 61000-4-4; burst; length > 30 m
± 1 kV according to IEC 61000-4-5; surge; length > 30 m
± 4 kV contact discharge in accordance with IEC 61000-4-2
± 8 kV air discharge in accordance with IEC 61000-4-2
10 V/m, 80 MHz to 1 GHz, 80% AM in accordance with
IEC 61000-4-3
3 V/m, 1.4 GHz to 2 GHz, 80% AM in accordance with IEC
61000-4-3
1 V/m, 2 GHz to 2.7 GHz, 80% AM in accordance with IEC
61000-4-3
10 V, 150 KHz to 80 MHz, 80% AM in accordance with IEC
61000-4-6