Siemens Sinamics Connect Series Operating Instructions Manual page 94

Hide thumbs Also See for Sinamics Connect Series:
Table of Contents

Advertisement

Appendix
A.1 Assembly of cable terminals on the device side
Assembling the terminals for cable with ferrule
Stranded conductor with insulated ferrule
(cross section: 0.25 mm
2
1. Remove the specified length (see illustration) of the outer sheath of the cable, and make a PE conductor from the
braided shield.
2. Strip the specified length (see illustration) of the insulation at the end of the wire.
3. Insert the stripped end into the pin-type terminal.
4. Crimp the terminal using a crimping tool, and then cut off the excess part of the wire.
92
to 0.5 mm
)
2
Stranded conductor with non-insulated ferrule
(cross section: 0.25 mm
2
Operating Instructions, 10/2018, A5E45421408
to 0.5 mm
)
2
SINAMICS CONNECT