Troubleshooting; General Errors; Technical Data; Connectors And Power Supply - Siemens SIMATIC RTLS Series Device Manual

Localization systems
Hide thumbs Also See for SIMATIC RTLS Series:
Table of Contents

Advertisement

4 Troubleshooting

4.1 General errors

Fault detection
Wireless module does not
react, all LEDs are off
Power LED (red) flashes
every second
Radio LED (yellow) is off
Network LED (blue) is off

5 Technical data

5.1 Connectors and power supply

Connectors and power supply
Voltage
Power consumption
Power connector

Ethernet

5.2 Ethernet
Ethernet
Ethernet
Duplex mode
DHCP
PoE
12
Cause of error
Module is not connected or power
supply is not switched on.
Undervoltage
No connection to the WLS
No network connection established
(LAN)
8 ... 30 V DC, nominal 24 V DC
9 W
3-pole plug-in connector with screw terminal Bulgin Buccaneer®
PX0412/03P
RJ45 Ethernet via connector socket Amphenol LTW RCP-5SPFFH-
TCU7001
Matching plug: Amphenol LTW PCP-00AMMA-TLM7001
10/100MBit auto-detect
Half- or full-duplex
Yes
IEEE 802.3af
class 0, power level 0.44 ... 12.94 W
Troubleshooting
Check module's power supply
Check power supply
Activate localization network
Check local IT network, check
firewall
Device manual, 10/2018, C79000-G8976-C515-01